[!INCLUDEappliesto-ss-xxxx-xxxx-xxx-md]
| Product Name | [!INCLUDEssNoVersion] |
| Event ID | 17083 |
| Event Source | MSSQLSERVER |
| Component | SQLEngine |
| Symbolic Name | P3_HEKATON_NOT_ATOMIC |
| Message Text | The body of a natively compiled stored procedure must be an ATOMIC block. |
The body of a natively compiled stored procedure did not have an ATOMIC block.
A natively compiled stored procedure must contain an ATOMIC block. For example:
BEGIN ATOMIC WITH (TRANSACTION ISOLATION LEVEL = SNAPSHOT, LANGUAGE= N'us_english')
For more information, see In-Memory OLTP (In-Memory Optimization).